tap water and sulfuric acid magnetic flow meter
- Lead Time:
-
Quantity(Sets) 1 - 3 >3 Est. Time(day) 5 Negotiable
- Place of Origin:
-
Henan, China (Mainland)
- Brand Name:
-
AFT
- Model Number:
-
AFTLD
- Product Name:
-
tap water and sulfuric acid magnetic flow meter
- Medium:
-
Liquid
- Accuracy:
-
0.5%
- Power supply:
-
220VAC/ 24VDC
- Material:
-
carbon steel
- Electrode material:
-
316L/Hastelloy C22 / Platinum / Titanium / Tantalum
- Output:
-
4-20mA /RS485
- Protection grade:
-
IP65 / IP 68(optional)
- Liner material:
-
PTFE/PFA/F46/Neoprene/Polyurethane
- Connection:
-
Flange: DN6-DN3000
- Supply Ability:
- 5000 Set/Sets per Year tap water and sulfuric acid magnetic flow meter
- Packaging Details
- tap water and sulfuric acid magnetic flow meter: Each of our meter after factory calibration, according to different size do packaging, usually, below 100 mm flow meter will be used in fine carton packaging, above 100 mm flow meter will be used free of steam box packaging. We will ensure that each flow meter, safe to reach your hands
- Port
- Qingdao/Shanghai/Tianjin/Dalian
- Lead Time :
-
Quantity(Sets) 1 - 3 >3 Est. Time(day) 5 To be negotiated
tap water and sulfuric acid magnetic flow meter

tap water and sulfuric acid magnetic flow meter
Main power | AC220V 50HZ / DC24V | |
Power consumption | <15W (And set with sensor supporting power consumption ) | |
Display and push buttons | The big screen LCD display with back lighting can display the instantaneous flow ,total flow and percentage of flow as well as alarm display ,four thin-film touch nubs ,which is used to data set . | |
Accumulator | Forward total quantity ,reverse total quantity | |
Output signal | Bi-direction with two ways ,Isolation 0-10mA/4-20mA | |
Load resistor:0-10Ma;0-1.5KΩ;4-20Ma;0-750Ω | ||
Frequency output | Forward & reverse flow output with frequency range set between 1-5000Hz.The external voltage must be lower than 35V and the max output and the max output current is 50Ma when the transistor is turned on | |
Alarm output | Two outputs from the collectors of photoelectric isolate transistors are for alarm signals .The external voltage must be lower than 35V and the max output current is 250Ma when the transistor is turned on.Alarm status:Activates when the measured pipes are empty ,the excitation circuits are broken or the volume of flow rate exceeds the value designed limits. | |
Pulse output | For pulse output in forward and reverse flow measurement ,upper frequency of pulse output can be up to 5000 CP/S relevant value of pulse is from 0.0001 to 1.0 M3/P .The width of pulse can be set to 20ms or squired wave from automatically.The collector of transistor with photoelectric is open circuited.The external voltage must be lower than 35 V and maximum output current is 250Ma when the transistor is turned on . | |
Accuracy | ±0.5% of the value displayed ,±0.3% or ±0.2% are selectable. | |
Damping time constant | Continuous variable from 0-100 s (90%)can be selected by group | |
Communication | RS232 ,RS485 or HART Communication are selectable ,with lighting resistance | |
Power failure | An anti-failure clock is designed in the flow meter which can save the power failure records for 16 times (10 years) | |
Protection class | IP65 | |
Ex-proof Mark | Exd IIBT4 |
Main performances of the liner materials:
// AFT INSTRUMENT
INSTALLATION CASE OF tap water and sulfuric acid magnetic flow meter
We are the manufacturer of flow meter, specializing in the production of electromagnetic flow meter, turbine flow meter, vortex flow meter, throttling devices and other flow meter. Our flow meters have been sold to the developed countries ,such as the United States, Australia and so on and the developing countries,such as India, Malaysia, Nigeria and so on.
// AFT INSTRUMENT
PRODUCT PROCESS OF tap water and sulfuric acid magnetic flow meter
Our company has strict quality control from product design, raw material procurement and processing, manufacturing and assembly, inspection and verification to every stage of product release, scientific management, strict process, advanced equipment and Professional team as a guarantee of quality products.
Each of our meter after factory calibration, according to different size do packaging, usually, below 100 mm flow meter will be used in fine carton packaging, above 100 mm flow meter will be used free of steam box packaging. We will ensure that each flow meter, safe to reach your hands.
- “Time is gold ”for you and for us, we have professional team work who can make nice quality in short time.
“With us your money in safe your business in safe ”full refund in case of bad quality or delay delivery time , we also accept payment by paypal.
- We are the leader of flow meter manufacturer in china.
- Alibaba Assessed Gold Supplier.
- Inspected by the Inspection Institution of Bureau Veritas Certification.
- 100% QC inspection Before Shipping.
- Exports to many countries.
Our sales staff have been trained in professional knowledge and information, so we can provide the most professional services to our customers according to their needs;Our technical staff have conducted skills training and practiced in the workshop, with professional theoretical knowledge and rich practical experience.
In order to ensure the quality of each product and to provide better service for customer. Our company has received a number of certifications, including CE certification, explosion-proof certification, MSES certification and some other internationally recognized certifications.
We have participated in many exhibitions, such as Beijing Multinational Instruments Exhibition, Shanghai International Instrument Exhibition, Canton Fair and so on. At the exhibition, many customers were met and orders were placed through subsequent exchanges and interactions.
You May Like
You May Like
Transaction Level: | |
---|---|
14 Transactions |
20,000+
The supplier’s transactions conducted via Alibaba.com in the past 6 months.
|
Response Time | <24h |
Response Rate | 90% |